The 10-100kVA Silent Yangdong Diesel Generator sets a new benchmark for standby power reliability, merging Yangdong’s 60+ years of engine manufacturing expertise with advanced noise reduction technology. Built around Yangdong’s high-performance Y4105D (10-50kVA) and YD4EZLD (50-100kVA) engines—specifically engineered for low vibration and extended service life—this generator achieves impressive ≤80dB(A) noise levels at 7m (equivalent to a household vacuum) and 218g/kWh fuel efficiency (tested on 50kVA model at 75% load). Its robust design ensures seamless operation in extreme ambient conditions ranging from -20°C to 45°C, while the IP23-rated weatherproof enclosure (resistant to dust and water spray) and compact footprint (≤1,200kg for 100kVA unit) make it suitable for both urban installations (e.g., rooftop utility rooms) and remote sites.
Ultra-Reliable Performance: Constructed with high-strength cast iron cylinder blocks (reducing thermal deformation) and forged steel crankshafts (enhancing wear resistance), ensuring 15,000-hour overhaul intervals—significantly reducing long-term maintenance costs for continuous commercial use .
Cold-Start Reliability: Enhanced with an optional pre-heating system and low-viscosity oil circulation design, enabling reliable -30°C cold-start capability—critical for winter operations in northern climates or high-altitude regions .
Certifications: Fully CE-certified and compliant with ISO 8528-5 (generator set performance) standards, ensuring seamless integration into global power systems and meeting international safety requirements .
Commercial Buildings: Delivers instant backup power for hotels (sustaining elevators, HVAC, and guest amenities), hospitals (supporting life-sustaining equipment in ICUs and operating theaters), and shopping centers (maintaining refrigeration and security systems) via automatic transfer switches (ATS) that activate within seconds of grid failure.
Construction Sites: Powers electric drills, concrete mixers, and temporary lighting in remote locations, with IP54-rated enclosures providing enhanced protection against dust ingress and water splashes common in construction environments.
Data Centers: Supports 99.99% uptime for server farms and cooling systems, with optional redundant configurations (N+1) to eliminate single points of failure in mission-critical IT infrastructure.
Q: What is the typical response time during grid failure?
A: Equipped with a high-speed electric starter and optimized ignition system, it achieves ≤8 seconds start-up time, with full load synchronization within 12 seconds—ensuring uninterrupted power for time-sensitive applications like medical equipment and data servers .
Q: Can it integrate with renewable energy systems?
A: Yes, its flexible control system allows seamless integration with solar/wind hybrid systems, enabling peak shaving (reducing diesel usage during high renewable generation) and load balancing (supplementing renewable output during lulls), which can reduce diesel consumption by up to 25% in hybrid setups .
50HZ | |||
Genset model | Output power | Engine model | |
KW | KVA | ||
NPYD-9GF | 9 | 11.25 | YD380D |
NPYD-10GF | 10 | 12.5 | YD385D |
NPYD-12GF | 12 | 15 | YD480D |
NPYD-15GF | 15 | 18.75 | YND485D |
NPYD-20GF | 20 | 25 | YSD490D |
NPYD-24GF | 24 | 30 | Y4100D |
NPYD-30GF | 30 | 37.5 | Y4102D |
NPYD-40GF | 40 | 50 | Y4102ZD |
NPYD-50GF | 50 | 62.5 | Y4105ZLD |
NPYD-60GF | 60 | 75 | YD4EZLD |
60HZ | |||
Genset model | Output power | Engine model | |
KW | KVA | ||
NPYD12GF | 10 | 12.5 | YD380D |
NPYD15GF | 12 | 15 | YD385D |
NPYD18GF | 15 | 19 | YD480D |
NPYD22GF | 18 | 23 | YND485D |
NPYD28GF | 22 | 28 | YSD490D |
NPYD30GF | 24 | 30 | Y490D |
NPYD35GF | 28 | 35 | Y495D |
NPYD40GF | 32 | 40 | Y4100D |
NPYD44GF | 35 | 44 | Y4102D |
NPYD50GF | 40 | 50 | Y4105D |
NPYD63GF | 50 | 63 | Y4102ZLD |
NPYD72GF | 58 | 73 | Y4105ZLD |
NPYD80GF | 64 | 80 | YD4EZLD |
NPYD100GF | 80 | 100 | Y4110ZLD |
NPYD110GF | 90 | 112 | YD4GZLD |